CHAPTER 2
Installation
47
• Cabling: the pin on the connector of the Adcon
RTUs that the sensor cable is connected to (refer to
the addIT and addWAVE user manuals for a
description of the connectors).
WARNING If you plan to add your own sensors to an Adcon RTU,
note that the cable between the sensor and the RTU must be
shielded, with the shielding properly connected to the casing
ground of the RTU. In addition, the maximum cable length should
not exceed 10 m (33 ft.).
c. Specific entries for SDI-12 sensors (see Figure 19) are:
• Address: type the sensor’s SDI-12 address. Note
that this is the default address; you can still change
the sensor’s address when you connect it to an RTU
(see also “SDI-12 Sensors” on page 43). The default
address is usually 0, but you can get more details
from the sensor manufacturer.
• Method: this parameter is sensor-dependent and
you will need to determine it by consulting the
sensor manual. Typically it is 0 (corresponding to the
SDI-12 M0 request); in case of doubt, consult the
sensor manufacturer.
Figure 19. Defining a custom SDI-12 sensor
• Index: this parameter is sensor dependent and you
will need to determine it by consulting the sensor
manual. It represents the position of a sensor value