Adcon A720 Guia do Utilizador Página 91

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 146
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 90
CHAPTER 3
Operations at the Application Level
91
PARAMETERS None.
R
ETURNS A list of current status parameters. The list is self-explanatory.
R
EMARKS GET only.
E
XAMPLE gprsstat
RTU Address Port NPND POLL TIME
---------------------------------------------------
34990 172.16.0.66 45964 0 0 43693
OK
GPRSDISCONNECT
DESCRIPTION Close existing GPRS connection to device.
P
ARAMETERS Device ID.
R
ETURNS OK or error.
R
EMARKS None.
E
XAMPLE gprsdisconnect 34990
OK
Error Messages
The emu3ap software might return any of several error messages.
Some are self-recoverable after a retry and others are simply
warnings. These messages are returned instead of the OK prompt.
1 — Nonexistent command
2 — CLI buffer overflow
3 — Internal error
5 — Invalid or missing parameter
10 — Device not found
11 — Device already exists
13 — No more space for device descriptors
14 — No more records for the requested device
15 — Remote device currently unavailable (radio connection
temporarily interrupted)
18 — Reserved device numbers (that is, 0)
20 — Incorrect time supplied, conversion not possible
Vista de página 90
1 2 ... 86 87 88 89 90 91 92 93 94 95 96 ... 145 146

Comentários a estes Manuais

Sem comentários