CHAPTER 3
Advanced Functions
78
statusformat=N|T
Specifies whether the status of a measurement value is printed
as a number (statusformat=N) or as strings OK, BAD, MISSING
(default, or statusformat=T).
bad=yes|no
Specifies whether measurement values with status=bad are
output (bad=yes) or not (default, or bad=no).
missing=yes|no
Specifies whether measurement values with status=missing are
output (missing=yes) or not (default, or missing=no).
R
ETURNS Text export data.
R
EMARKS To use this command, this feature has to be bought aditionally. A
special license key is required.
E
XAMPLE getdata-csv
rtulist=2&delimiter=%09&timestamp=20040101T00:00
:00
Requests all TAG data for the RTU with node ID 2, using the tab
character as field delimiter, beginning with January 1st, 2004 at
midnight.
getdata-csv
rtulist=2,34&timestamp=20040101T00:00:00&datefor
mat=MM/DD/YY hh:mm:ss
Requests all TAG data for the RTUs with node IDs 2 and 34,
beginning with January 1st, 2004 at midnight, and date output is
formatted as month/day/year without century hour:minute:second
(a common format for office programs like OpenOffice.org-Calc or
Microsoft Excel).
getdata-csv
taglist=3,4&timestamp=20040101T00:00:00&dateform
at=MM/DD/YY hh:mm:ss
Same as above, but only returns data for the sensors with node
IDs 3 and 4.!
SDICHANGED
DESCRIPTION Get/set “SDI configuration changed” flag for a specific device.
P
ARAMETERS Device ID and “SDI configuration changed” flag.
R
ETURNS OK or an error message.